De Pala srl
It En De

Module BF0( 1 circulator) for biomass - heating system separation

Module BF0( 1 circulator) for biomass - heating system separation
Module BF0( 1 circulator) for biomass - heating system separation

Description

BOX FIRE BF0 is a preassembled module specially developed to integrate an open circuit solid fuel heat source (Fireplace with built-in circulation pump) to a house heating system normally feeded by an expansion tank Gas Boiler. 
The module separates the heating sources and manages the functionning of the Boiler based on the temperature of the Fireplace. Moreover, by means of a heat exchanger, it transfers efficiently the heat geneated by the Fireplace to the heating system.

 

Primary circuit (Fireplace) pump PTC starts when fireplace reaches a temperature of 30 °C, then at 70 °C secondary circuit (heating plant) pump PIR starts and simultaneously boiler circulation pump is switched off. From that moment the fireplace starts heating up the house. All electric components are controlled by means of a control unit FDG.

 

Related Product Codes

BF03CR

BOLIER-FIRE PLACE CONNECTION UNIT BF0 POWER 25Kw WITH CONTROL UNIT AND BOILER CONNECTION PIPES - NO COVER

BF05AR

BOLIER-FIRE PLACE CONNECTION UNIT BF0 POWER 45Kw WITH CONTROL UNIT WITHOUT COVER

BF04AR

BOLIER-FIRE PLACE CONNECTION UNIT BF0 POWER 35Kw WITH CONTROL UNIT WITHOUT COVER

BF03AR

BOLIER-FIRE PLACE CONNECTION UNIT BF0 POWER 25Kw WITH CONTROL UNIT WITHOUT COVER

BF04CC

BOLIER-FIRE PLACE CONNECTION UNIT BF0 POWER 35Kw WITH COVER & CONTROL UNIT AND BOILER CONNECTION PIPES

BF03CC

BOLIER-FIRE PLACE CONNECTION UNIT BF0 POWER 25Kw WITH COVER & CONTROL UNIT AND BOILER CONNECTION PIPES

BF05AC

BOLIER-FIRE PLACE CONNECTION UNIT BF0 POWER 45Kw WITH COVER & CONTROL UNIT

BF04AC

BOLIER-FIRE PLACE CONNECTION UNIT BF0 POWER 35Kw WITH COVER & CONTROL UNIT

BF03AC

BOLIER-FIRE PLACE CONNECTION UNIT BF0 POWER 25Kw WITH COVER & CONTROL UNIT

BF04CR

BOLIER-FIRE PLACE CONNECTION UNIT BF0 POWER 35Kw WITH CONTROL UNIT AND BOILER CONNECTION PIPES - NO COVER

BF03AN

BOLIER-FIRE PLACE CONNECTION UNIT BF0 POWER 25Kw NO COVER - NO CONTROL UNIT

BF04AN

BOLIER-FIRE PLACE CONNECTION UNIT BF0 POWER 35Kw NO COVER - NO CONTROL UNIT

BF05AN

BOLIER-FIRE PLACE CONNECTION UNIT BF0 POWER 45Kw NO COVER - NO CONTROL UNIT

BF03CN

BOLIER-FIRE PLACE CONNECTION UNIT BF0 POWER 25Kw NO COVER NO CONTROL UNIT WITH BOILER CONNECTION PIPES

BF04CN

BOLIER-FIRE PLACE CONNECTION UNIT BF0 POWER 35Kw NO COVER NO CONTROL UNIT WITH BOILER CONNECTION PIPES

technical support +39 0434 920466